TOC PAT700

The PAT700 TOC analyzer fully complies with all global pharmacopeias (USP, EP, JP) requirements. Each sample is fully oxidized guaranteeing the most accurate TOC result that follows EP2.2.44 guidelines. Production uptime is assured with the PAT700 main and standby dual UV lamp design, making it the ideal choice for on-line TOC release. Save time and money - the PAT700 can be installed online and run up to 4 grab samples offline.

 

PAT700 TOC Analyzer Product Specifications

TOC Operating Range 0.5 to 2,000 ppb as Carbon Display Resolution 0.1 ppd Accuracy +/-1 ppd or +/-5% whichever is greater Repeatability +/-0.3 ppd or +/-1% whichever is greater Limit of Detection 0.5 ppb Maximum Input Conductivity 0.2 uS/cm for all waters, 1.0 uS/cm for all neutral waters, 5.0 uS/cm for water with CO2 as the sole conductive species Conductivity Conductivity Range 0.05 to 150 uS/cm (@25* C) Display Resolution 0.01 uS/cm Conductivity Accuracy +/-2% over full range (uncompensated) Resistivity Resistivity Range 0.2 to 18 MQ-cm (@25*C) Display Resolution 0.01 over full range Available Modes Temperature compensated to 25*C, or uncompensated Temperature Ambient Operating Range 10 to 40*C (50 to 104*F) Measurement Accuracy +/-0.4*C Sample Water Range 5 to 95*C (41 to 203*F) Display Resolution 0.1 over full range Physical Specs UV Lamps 2, with UV Detect technology Interface/Display Color with touch screen Maximum Altitude 4,000 m (13,125) User I/O Wiring Three, 3/4-inch conduit openings or quick disconnect fittings Standards System Onboard, Automated Standards Introduction System (OASIS) Dimensions 59.7 w X 22.9 d X 25.4 h (23.5 X 9 X 10 inches) Weight 13.6 kg (30 lbs) Sample Inlet Flow Rate Range 60 mL/min to 300 mL/min Sample Inlet Pressure Range 10 to 100 psi (69 to 690 kPa) Compliance Installation Category II Pollution Degree 2, IEC 61010-1 CE Compliance EN 61010-1 and EN 61326 Safety Rating ETL, conforming to UL 61010-1 and CSA 22.2 No. 61010-1 Enclosure Rating Conduit version: IP56 Quick connect version: IP46 Release Tests USP <643>, USP <645>, JP 16, EP 2.2.44 New Features CIP Selectable mode for Clean-In-Place analysis Dual Stream option Toggle or programmable stream switching Excursion sampling Minimum flow rate to fill excursion bottle = 160 mL/min Rouge detection Identifies oxidation cell contamination from roughing ASX 7200 Auto Sampler Specifications

   Physical Specs Vial Capacity 36 Grab sample bottles HDPE or Borossilicate USP Type 1 glass     Dimensions 45.7 cm X 36.6 cm X 53.7 cm (HxWxD)     Weight 21 kg (45 lbs)   Communications Communications RS232 interface with PAT700 - No external PC required   Environment Ambient Environment 10 - 40*C, 5 - 95% non-condensing RH   Power Power Requirements 100 - 240 VAC +/- 10%, 4.4A  
āđāļšāļšāļŸāļ­āļĢāđŒāļĄāļŠāļąāđˆāļ‡āļ‹āļ·āđ‰āļ­
āļŠāļ·āđˆāļ­ *
āļ™āļēāļĄāļŠāļāļļāļĨ *
āļŠāļ·āđˆāļ­āļšāļĢāļīāļĐāļąāļ—
āđ€āļšāļ­āļĢāđŒāļ•āļīāļ”āļ•āđˆāļ­ *
āļ­āļĩāđ€āļĄāļĨ *
LINE ID
āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āļŠāļīāļ™āļ„āđ‰āļē

āļŠāļīāļ™āļ„āđ‰āļēāđ„āļĄāđˆāđ€āļžāļĩāļĒāļ‡āļžāļ­

āļŠāļīāļ™āļ„āđ‰āļēāļŦāļĄāļ”

Visitors: 615,264